General: 16” GIW Booster Model BO-7650D-SP
Overall length |
22’ |
(6.7m) |
Overall width |
7’-4” |
(2.2 m) |
Assembled height |
10’-5” |
(3.2 m) |
Approximate weight |
34,000 lb |
(15.4 t) |
Dredge Pump:
The dredge pump is GIW model LSA39. The pump slurry piping has a 16” (400 mm) suction diameter and a 16” (400 mm) discharge. The impeller diameter will be 39” (991 mm)
Dredge Pump Drive
The dredge pump drive features marine style reduction gear and an elastomer coupling.
Dredge Pump Prime Mover
Caterpillar model 3412E diesel engine rated 860 bhp (641 kW) and complete with silencer. The engine package features gages, alarms, and shutdown systems. Engine is radiator cooled.
Dredge Pump Reduction
Twin Disc model 5202 with a 2.92:1 ratio
Service Water Pump
The service water pump’s primary use is for the dredge pump packing gland. The service water pump will also be used as the source for the raw water wash down system and the dredge pump transmission cooling system. The service water pump is of the centrifugal design with a single open end suction protected by a strainer. The service water pump will be supplied with a 3” (75 mm) suction x 2” (50 mm) discharge.
Safety
Equipment guards are provided for the safety of the crew and for compliance to DSC strict building codes. The booster station will be equipped with a fire extinguisher.
Booster Automation/Control Package:
The booster control package consists of a PLC, touch screen operator interface, transmitters, radio modem and enclosure with mounting brackets. The sensors that will be supplied are discharge pressure, inlet pressure, and service water pressure.
The Section 1 Equipment/Specifications:
Booster panel will have start/stop switches for the main pump and service water pump. The panel also has a booster mode switch and a touch screen. The touch screen will display data, alarms and it allows the operator to change control and alarm set points. The booster has an auto and manual mode. The auto mode is controlled off the inlet pressure and discharge pressure and the manual mode allows you to control the booster manually.
Electrical System
Coatings finished 2018
Non-immersion:
Engine room and equipment skids: